Why the study?
Epicardial adipose tissue characteristics correlate independently with various cardiovascular diseases, making accurate, fully automatic EAT segmentation and quantification on CCTA an essential research aim.
Does a fully automatic deep learning-based pipeline accurately segment and quantify epicardial adipose tissue volume in CCTA scans compared to manual expert delineation?
Does a fully automatic deep learning-based pipeline accurately segment and quantify epicardial adipose tissue volume in CCTA scans compared to manual expert delineation?
Answers are grounded in this paper and cite their sources.
A fully automatic deep learning-based method accurately segments and quantifies epicardial adipose tissue volume from CCTA scans, performing comparably to independent expert radiologists.
Purpose Epicardial fat is the adipose tissue between the serosal pericardial wall layer and the visceral layer. It is distributed mainly around the atrioventricular groove, atrial septum, ventricular septum and coronary arteries. Studies have shown that the density, thickness, volume and other characteristics of epicardial adipose tissue (EAT) are independently correlated with a variety of cardiovascular diseases. Given this association, the accurate determination of EAT volume is an essential aim of future research. Therefore, the purpose of this study was to establish a framework for fully automatic EAT segmentation and quantification in coronary computed tomography angiography (CCTA) scans. Methods A set of 103 scans are randomly selected from our medical center. An automatic pipeline has been developed to segment and quantify the volume of EAT. First, a multi‐slice deep neural network is used to simultaneously segment the pericardium in multiple adjacent slices. Then a deformable model is employed to reduce false positive and negative regions in the segmented binary pericardial images. Finally, the pericardium mask is used to define the region of interest (ROI) and the threshold method is utilized to extract the pixels ranging from −175 Hounsfield units (HU) to −15 HU for the segmentation of EAT. Results The Dice indices of the pericardial segmentation using the proposed method with respect to the manual delineation results of two radiology experts were 97.1% 0.7% and 96.9% 0.6%, respectively. The inter‐observer variability was also assessed, resulting in a Dice index of 97.0% 0.7%. For the EAT segmentation results, the Dice indices between the proposed method and the two radiology experts were 93.4% 1.5% and 93.3% 1.3%, respectively, and the same measurement between the experts themselves was 93.6% 1.9%. The Pearson’s correlation coefficients between the EAT volumes computed from the results of the proposed method and the manual delineation by the two experts were 1.00 and 0.99 and the same coefficients between the experts was 0.99. Conclusions This work describes the development of a fully automatic EAT segmentation and quantification method from CCTA scans and the results compare favorably with the assessments of two independent experts. The proposed method is also packaged with a graphical user interface which can be found at https://github.com/MountainAndMorning/EATSeg .
No takes yet. Share an insight, caveat, or question.
Li et al. (2021) studied this question.