Why the study?
Wearable cardioverter-defibrillators protect against sudden cardiac death as bridging therapy, but gender differences in patients wearing them required exploration in a multicenter cohort.
Are there gender differences in compliance, mortality, and appropriate shocks among patients treated with a wearable cardioverter-defibrillator?
Are there gender differences in compliance, mortality, and appropriate shocks among patients treated with a wearable cardioverter-defibrillator?
Compliance with wearable cardioverter-defibrillators is excellent and comparable between genders, with similar mortality and device implantation rates, despite differences in underlying cardiomyopathy etiologies.
Gender differences in WCD patients remain poorly defined; this Level 5 analysis leaves open whether sex-specific risk stratification is warranted.
Aims The treatment with the wearable cardioverter defibrillator (WCD) may protect against sudden cardiac death (SCD) as a bridging therapy until a cardioverter-defibrillator may be implanted. We analyzed in a multicenter setting a consecutive patient cohort wearing WCD to explore gender differences. Methods and results We analyzed 708 consecutive patients, 579 from whom were males and 129 females (age, 60.5±14 vs. 61.6±17 years old; p=0.44). All patients were divided into age quartiles for analysis. While the rate of ischemic cardiomyopathy (ICM) as a cause of prescription of WCD was significantly higher in males as compared to females (42.7% vs. 26.4%; p=0.001), females received it more frequently due to non-ischemic cardiomyopathy (NICM) (55.8% vs. 42.7%); p=0.009). The wear time of WCD was equivalent in both groups (21.1±4.3 hours/days in males vs. 21.5±4.4 hours/days in females; p=0.27; and 62.6±44.3 days in males vs. 56.5±39 days in females; p=0.15). Mortality was comparable in both groups at 2-year-follow-up (6.8% in males vs. 9.7% in females; p=0.55). Appropriate WCD shocks and the incidence of device implantations were similar in both groups (2.4% in males vs. 3.9% in females; p=0.07) (35.1% in males vs. 31.8% in females; p=0.37), respectively. In age quartile analysis, compliance was observed more in older patients as compared to adult patients (87.8% vs. 68.3%; p<0.001). Conclusion Compliance for wearing WCD was excellent regardless of gender. Furthermore, mortality and the incidence of device implantations were comparable in both groups. Appropriate WCD shocks tended to be higher in females as compared to males.
No takes yet. Share an insight, caveat, or question.
Abumayyaleh et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: