Key result
~42% of WCD users proceed to ICD implantation, with females receiving fewer devices than males.
Why the study?
Does the wearable cardioverter defibrillator provide safe protection and high adherence in patients with transient risk of sudden cardiac death?
Cohort (n=130)
No
Does the wearable cardioverter defibrillator provide safe protection and high adherence in patients with transient risk of sudden cardiac death?
The wearable cardioverter defibrillator is safe and associated with high daily adherence in patients with transient risk of sudden cardiac death, effectively bridging them to reassessment for permanent ICD implantation.
Real-world WCD data show high adherence and low inappropriate shocks; leaves open whether bridging reduces unnecessary ICD implants.
Background Nowadays sudden cardiac death (SCD) remains a major cause of death, despite the recent progress in prevention and interventions of cardiac disease. In case of transient risk of SCD, the use of a wearable cardioverter defibrillator (WCD) is recommended in current guidelines. The purpose of this study was to investigate the safety and the adherence to WCD in a real world population; moreover, we reviewed the rate of ICD implantation after WCD use. Methods We considered consecutively 130 patients discharged from our cardiology department for potentially transient high risk of SCD, weared a WCD from August 2017 to December 2025. The patients were discharged with WCD protection and followed through remote monitoring or outpatient. A clinical and echocardiographic evalutation was performed at baseline and at the end of the WCD use period. Results Out of 130 patients, with average age 64,9±11,9 years old and baseline average left ventricular ejection fraction (LVEF) 31 ±9,5,79 % were males,72% suffered from arterial hypertension, 25% diabetes mellitus 16% chronic renal failure ,6% previous stroke, 22% atrial fibrillation (AF). 57% of these patients weared WCD for severe systolic dysfunction in ischemic cardiac disease, 3% after removal of an infected ICD, 40% after newly diagnosed cardiomyopathy. 84% patients were in therapy with beta blockers, 39% with sacibitril/valsartan and 38% with glifozine. The average wearing time of WCD was 61±42,9 days and 23±2,4 hours daily. We received these events: 2 sustained ventricular tachicardia, 6 non sustained ventricular tachicardia (TV) 4 atrial fibrillation. One patient received inappropriate shock. At the end of the WCD use,42% of patients proceeded to device implantation. At last follow up 14 deaths was detected in patients that weared WCD due to advanced heart failure. Considering sex difference, we observed in females a better baseline LVEF (f 34±9vs m 29±8,1 p=0,03) and a significant lower ICD implantation rate at the end of WCD use [f 7(26%) vs m 48(55%)p=0.04]. During wearing time 7 Tv occurred in males and 1 in females. Conclusions In our experience we may confirm that WCD use is, effective, safe and with a good adherence in all patients. The WCD allows resources saving not only during therapy titration but also by enabling arli discharge supporting appropriate decision making regarding ICD implantation. Females presented a lower ICD implantation rate
No takes yet. Share an insight, caveat, or question.
Bolognesi et al. (2026) conducted a cohort in Transient risk of sudden cardiac death (n=130). Wearable cardioverter defibrillator was evaluated on ICD implantation. Among patients using a wearable cardioverter defibrillator for transient sudden cardiac death risk, 42% proceeded to ICD implantation, with females having a lower rate than males (26% vs 55%, P=0.04).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: