Why the study?
Does three-dimensional volume-selective TSE MRI provide comparable measurements of carotid artery structure and function to two-dimensional ultrasound?
Does three-dimensional volume-selective TSE MRI provide comparable measurements of carotid artery structure and function to two-dimensional ultrasound?
Three-dimensional volume-selective TSE MRI shows good agreement with two-dimensional ultrasound for assessing carotid artery structure and function, with the added advantage of increased vessel coverage.
Supports MRI-ultrasound interchangeability for carotid assessment; leaves open prospective validation before clinical adoption.
PURPOSE: To compare a volume-selective three-dimensional turbo spin echo (TSE) technique with ultrasound (US) for assessing carotid artery wall structure and function. MATERIALS AND METHODS: A three-dimensional volume-selective TSE technique was used to image the carotid artery in 10 healthy subjects and five hypertensive subjects (each of whom were scanned three times while they received different hypertension treatments). Lumen and wall area were measured on MR images. Two-dimensional US measurements of the intima-media thickness (IMT) and lumen diameter were taken in three orientations through a single cross section. The lumen area change over the cardiac cycle was used to determine distension. For validation, a Bland-Altman analysis was used to compare the vessel wall and lumen areas measured by three-dimensional MRI volumes with those obtained by US scans. RESULTS: Agreement between the two methods was found. The mean difference in distension between US and MRI was 1.2% (+/-5.1%). For the wall area measurements, good agreement was shown, but there was a systematic difference due to the visualization of the adventitia by MRI. Both techniques offer an easy way to objectively measure lumen indices. MRI can provide the complete circumference over the length of a vessel, while US is flexible and relatively inexpensive. The application of US is limited, however, when subjects are poorly echogenic. A difference between hypertensive and healthy subjects was found. CONCLUSION: There was a good agreement between MRI and the clinically established two-dimensional US method. The MRI method has the advantage of providing increased vessel coverage, which permits one to assess localized abnormalities without assuming vessel uniformity.
No takes yet. Share an insight, caveat, or question.
Crowe et al. (2005) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: