Why the study?
Aldosterone and renin determinations play an important role in the etiological diagnosis of secondary hypertension, warranting analytical evaluation of new immunoassays.
Do the Lumipulse G Aldosterone and Renin assays provide comparable analytical performance to the iSYS system in patients with suspected primary aldosteronism?
Do the Lumipulse G Aldosterone and Renin assays provide comparable analytical performance to the iSYS system in patients with suspected primary aldosteronism?
The Lumipulse G Aldosterone and Renin assays demonstrate excellent analytical performance and clinical concordance with the iSYS system, supporting their routine use in medical laboratories.
New assays show comparable aldosterone/renin performance; leaves open clinical adoption pending outcome validation.
Objectives Aldosterone and renin determinations play an important role in the etiological diagnosis of secondary hypertension. The analytical performances of new aldosterone and renin immunoassays on the Lumipulse G600II ® system (Fujierbio) were investigated and compared with those of the iSYS ® system (IDS) on patients concerned by medical investigations in a context of suspected or proven Primary aldosteronism. Methods By using the Lumipulse ® G Aldosterone and Renin assays we performed imprecision study, linearity and method comparison (n=107). Accuracy of this new renin assay was tested using the International Standard (WHO IS 68/356). We also assessed the equivalence of the different samples types (n=29). Results The imprecision evaluation showed all CVs <3% and <6% for Lumipulse ® G Aldosterone and Renin assays respectively. The linearity was excellent over the clinical range and the comparison with the iSYS ® assays (n=79) showed a strong correlation (R 2 =1) despite a slight tendency to underestimation (bias of −17.53 pg/mL or 48.56 pmol/L for aldosterone and −15.395 pg/mL for renin). Moreover, the contingency studies based on diagnostic criteria showed that Lumipulse ® G results lead to the same clinical diagnosis that iSYS ® results. A clear correlation was obtained between EDTA and heparin plasma as well as with the serum for all range of measures. Conclusions The Lumipulse ® G Aldosterone and Renin assays present performances compatible with a routine use in medical laboratories. The precise quantification in the low range can be of interest in some clinical contexts especially standing/laying tests. However, the standardisation against the WHO International Standard Renin would be advisable.
No takes yet. Share an insight, caveat, or question.
Coulon et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: