Why the study?
What are the serial electrocardiographic changes in voltage, QRS vectors, and QRS-T angles during treatment for hypertension?
What are the serial electrocardiographic changes in voltage, QRS vectors, and QRS-T angles during treatment for hypertension?
Serial ECG changes during hypertension treatment may be more valuable than pretreatment abnormalities for diagnosing cardiac structural or functional disorders.
Answers are grounded in this paper and cite their sources.
ECG changes track hypertension treatment effects; hypothesis-generating for serial monitoring, needing prospective validation before clinical use.
Serial changes in voltage, QRS vectors, and QRS-T angles were studied in 44 patients who had shown improvement in their electrocardiograms during treatment for hypertension. Changes were observed in a number of electrocardiographic voltage criteria often used in the study of left ventricular hypertrophy. This is consistent with a change in the magnitude of the mean QRS vector and its reflection on a variety of ECG leads even if pretreatment records were normal. Improvement also occurred in the mean T vectors and the QRS-T angle. It is proposed that serial changes in the ECG might be of greater value than pretreatment abnormalities in diagnosing the disorder of cardiac structure or function that occurs in hypertension.
No takes yet. Share an insight, caveat, or question.
Dern et al. (1967) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: