Answers are grounded in this paper and cite their sources.
A 33.6-33.8 Gb/s burst-mode clock/data recovery circuit (BMCDR) is presented in this paper. To reduce the data jitter and generate the high-frequency output clock, theLCgated voltage-controlled oscillator is presented. To receive and transmit the broadband data, a wideband input matching circuit and a wideband data buffer are presented, respectively. The phase selector is proposed to overcome the false phase lock due to the full-rate operation. This proposed BMCDR has been fabricated in a 90 nm CMOS process. The measured peak-to-peak and rms jitters for the recovered data are 7.56 ps and 1.15 ps, respectively, for a 33.72 Gb/s, 211-1 PRBS. The measured bit error rate is less than 10-8for a 33.72 Gb/s, 27-1 PRBS. It consumes 73 mW without buffers from a 1.2 V supply.
No takes yet. Share an insight, caveat, or question.
Cho et al. (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: