Why the study?
In vivo comparison of invasive and non-invasive methods for wave intensity and wave power analyses in large arteries was lacking.
Non-invasive wave intensity and power indices correlate well with invasive measurements and can detect relative changes induced by hemodynamic perturbations despite variable absolute agreement.
May support non-invasive wave analyses in research; leaves open human validation and error quantification.
OBJECTIVE: Wave intensity (WI) and wave power (WP) analyses are powerful approaches for assessing ventricular-vascular interactions and arterial dynamics using invasive and non-invasive methods. However, in vivo comparison of these methods for large arteries is lacking. This study assessed agreement, correlation and relative changes in wave size in invasive and non-invasive aortic WI/WP analyses, and associated sources of error. APPROACH: The proximal descending thoracic aorta (DTA) of nine wethers was instrumented with a micromanometer and perivascular transit-time flow probe to measure high-fidelity blood pressure (P) and flow (Q) for invasive WI/WP analyses at baseline and during haemodynamic perturbations produced by cardiac pacing, distal DTA constriction and dobutamine-induced inotropic stimulation. In 212 experimental runs, concurrent echocardiographic DTA diameter and velocity (U) data were acquired for non-invasive WI/WP analyses, with measurement of forward compression wave (FCW), backward compression wave (BCW) and forward decompression wave (FDW) cumulative intensity (CI), cumulative power (CP) and wave-related pressure changes (ΔP). MAIN RESULTS: Although agreement between invasive and non-invasive FCW, BCW and FDW CI/CP measures was variable (bias -84% to +7%), correlation was good (R = 0.66-0.84), with lower bias and higher correlation for ΔP variables and similar relative changes in FCW and BCW CI/ΔP during haemodynamic perturbations. Main error sources were overestimation of invasive U due to assumed fixed vessel diameter, inaccuracies in non-invasive Q, and non-invasive underestimation of peak P/U and Q rates of change. SIGNIFICANCE: Despite variable agreement, non-invasive CI/CP indices correlate well with invasive measurements, and detect relative changes in major waves induced by haemodynamic perturbations.
No takes yet. Share an insight, caveat, or question.
Kowalski et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: