Answers are grounded in this paper and cite their sources.
Multilevel converters have received increased interest recently as a result of their ability to generate high quality output waveforms with a low switching frequency. This makes them very attractive for high-power applications. A cascaded H-bridge converter (CHB) is a multilevel topology which is formed from the series connection of H-bridge cells. Optimized pulse width modulation techniques such as selective harmonic elimination or selective harmonic mitigation (SHM-PWM) are capable of preprogramming the harmonic profile of the output waveform over a range of modulation indices. Such modulation methods may, however, not perform optimally if the dc links of the CHB are not balanced. This paper presents a new SHM-PWM control strategy which is capable of meeting grid codes even under nonequal dc link voltages. The method is based on the interpolation of different sets of angles obtained for specific situations of imbalance. Both simulation and experimental results are presented to validate the proposed control method.
No takes yet. Share an insight, caveat, or question.
Nápoles et al. (2012) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: