Why the study?
Is the transfemoral ACURATE-neo aortic bioprosthesis safe and effective in high-surgical risk patients with severe symptomatic aortic stenosis?
Is the transfemoral ACURATE-neo aortic bioprosthesis safe and effective in high-surgical risk patients with severe symptomatic aortic stenosis?
The initial North American experience demonstrates that the ACURATE-neo aortic bioprosthesis can be safely and successfully implanted via a transfemoral approach, providing excellent hemodynamic outcomes and a low rate of permanent pacemaker implantation.
Answers are grounded in this paper and cite their sources.
Early North American experience should not change TAVI practice; leaves open comparative safety and durability versus approved devices.
Background: Transcatheter aortic valve implantation (TAVI) has become a therapeutic alternative for patients presenting with severe symptomatic aortic stenosis and considered at high‐surgical risk. Paravalvular leak (PVL), conduction disorders, and coronary obstruction remain unresolved procedure‐related complications. The aim of this manuscript was to report the first North American experience with the ACURATE‐ neo TM aortic bioprosthesis and its ACURATE‐TF TM delivery system (Symetis S.A., Ecublens, Switzerland). Methods: Transfemoral ACURATE‐ neo TM aortic valve implantation was performed in 20 patients. Clinical and echocardiographic assessment was performed at baseline, postprocedure and at least 30 days. Outcomes were assessed according to valvular academic research consortium (VARC‐2) criteria. Results: The mean age was 82.7 ± 7.0 years with a mean logistic‐EuroSCORE‐II of 5.0 ± 2.9% and Society of Thoracic Surgeons score of 4.7 ± 2.3%. Device success was achieved in all patients. The mean distance between the aortic‐annulus and the left main coronary artery ostium was 14.3 ± 3.2 mm, and eight (40%) patients had <12 mm. At 30 days, there were no deaths, conversions to surgery, or major procedure‐related complications. New‐pacemaker implantation was required in one (5.3%) patient. ACURATE‐ neo TM implantation resulted in a significant reduction in mean transvalvular gradient (49.9 ± 15.8 to 9.7 ± 5.7 mm Hg, P < 0.0001) and increase in effective‐orifice area (0.65 ± 0.16 to 1.83 ± 0.36 cm 2 , P = 0.001) at hospital discharge. Paravalvular leak was absent in four (20%) patients, trace in nine (45%) patients, and mild in seven (35%) patients. Hospital discharge occurred at a mean of 7.0 ± 4.5 days, and all patients were in NYHA class I–II at a mean follow‐up of 8.6 ± 2.3 months. Conclusion: The present initial North American experience shows that the ACURATE‐ neo TM aortic bioprosthesis was safely and successfully implanted by transfemoral approach. The special design of this newer‐generation device affords a stable and predictable implantation, while providing optimal hemodynamic performance with a relatively low rate of PPI.
No takes yet. Share an insight, caveat, or question.
Bagur et al. (2016) studied this question.