Why the study?
Re-interventions and vascular complications occur after aortic coarctation repair, particularly with associated bicuspid aortic valve, motivating the use of 4D flow MRI to identify anatomic and hemodynamic factors for long-term clinical surveillance.
Does 4D flow MRI identify anatomic and hemodynamic derangements in pediatric patients with coarctation of the aorta compared to controls?
Does 4D flow MRI identify anatomic and hemodynamic derangements in pediatric patients with coarctation of the aorta compared to controls?
4D flow MRI demonstrates that despite repair, pediatric patients with coarctation of the aorta have persistent hemodynamic and flow derangements in the transverse arch and descending aorta.
4D flow MRI parameters may inform surveillance in repaired pediatric CoA; leaves open need for prospective validation before practice change.
BACKGROUND: Coarctation of the aorta (CoA) typically requires repair, but re-interventions and vascular complications occur, particularly with associated defects like bicuspid aortic valve (BAV). Magnetic resonance imaging (MRI) may identify anatomic and hemodynamic factors contributing to clinical complications. PURPOSE: To investigate 4D flow MRI characteristics in pediatric CoA to determine parameters for long-term clinical surveillance. STUDY TYPE: Retrospective. POPULATION: CoA (n = 21), CoA with BAV (n = 24), BAV alone (n = 29), and healthy control (n = 25). FIELD STRENGTH/SEQUENCE: A 1.5 T, 3D CE IR FLASH MRA, 4D flow MRI using 3D time resolved PC-MRI with velocity encoding. ASSESSMENT: Thoracic aorta diameters were measured from 3D CE-MRA. Peak systolic velocities and wall shear stress were calculated and flow patterns were visualized throughout the thoracic aorta using 4D flow. Repair characteristics, re-interventions, and need for anti-hypertensive medications were recorded. STATISTICS: Descriptive statistics, ANOVA with post hoc t-testing and Bonferroni correction, Kruskal-Wallis H, intraclass correlation coefficient, Fleiss' kappa. RESULTS: Patients with CoA with or without repair had smaller transverse arch diameters compared to BAV alone and control cohorts (P < 0.05), higher peak systolic flow velocities and wall shear stress compared to controls in the transverse arch and descending aorta (P < 0.05), and flow derangements in the descending aorta. The most common CoA repairs were extended end-to-end anastomosis (n = 22/45, 48.9%, age at repair 1 ± 2 years, seven re-interventions) and stent/interposition graft placement (n = 10/45, 22.2%, age at repair 12 ± 3 years, one re-intervention). Anti-hypertensive medications were prescribed to 33.3% (n = 15/45) of CoA and 34.4% of BAV alone patients (n = 10/29). DATA CONCLUSIONS: Despite repair, CoA alters hemodynamics and flow patterns in the transverse arch and descending aorta. These findings may contribute to vascular remodeling and secondary complications. 4D flow MRI may be valuable in risk stratification, treatment selection and postintervention assessment. Long-term, prospective studies are warranted to correlate patient and MRI factors with clinical outcomes. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 3.
No takes yet. Share an insight, caveat, or question.
Desai et al. (2021) studied this question.