Answers are grounded in this paper and cite their sources.
This study examines the rate of oxidative degradation of MEA under conditions typical of a CO 2 capture process. Experiments examined the effects of amine concentration, CO 2 loading, O 2 concentration, and agitation rate at 55 °C. Degradation rates were quantified by measuring the rate of NH 3 evolution from the amine solutions using FT-IR analysis. Results show that degradation rates are controlled by the rate of physical absorption of O 2 and NH 3 evolution rates ranged from 0.2 to 8.0 mM/h. Previous studies were re-examined and compared to the current study and appear to have been performed under conditions that were mass transfer limited. This would indicate the previous literature values for degradation kinetics were actually O 2 absorption rates. An estimate of the degradation rate for a CO 2 absorber was made assuming the degradation was controlled by the rate of O 2 absorption and was shown to be equal to or less than values reported in the literature.
No takes yet. Share an insight, caveat, or question.
Goff et al. (2004) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: