Why the study?
Heartbeat interval Lorenz plot imaging is promising for detecting AF during long-term monitoring, but the optimal segment window length for the images was unknown.
Does a specific segment window length optimize the detection of paroxysmal atrial fibrillation using Lorenz plot images and machine learning?
Does a specific segment window length optimize the detection of paroxysmal atrial fibrillation using Lorenz plot images and machine learning?
The optimal segment window length for detecting paroxysmal atrial fibrillation using 32x32-pixel Lorenz plot images and convolutional neural networks is 85 beats, which maximizes the positive likelihood ratio.
Answers are grounded in this paper and cite their sources.
Optimal 85-beat LP window may refine PAF detection in monitoring; leaves open prospective validation before clinical adoption.
BACKGROUND: Heartbeat interval Lorenz plot (LP) imaging is a promising method for detecting atrial fibrillation (AF) in long-term monitoring, but the optimal segment window length for the LP images is unknown. We examined the performance of AF detection by LP images with different segment window lengths by machine learning with convolutional neural network (CNN). LP images with a 32 × 32-pixel resolution of non-overlapping segments with lengths between 10 and 500 beats were created from R-R intervals of 24-h ECG in 52 patients with chronic AF and 58 non-AF controls as training data and in 53 patients with paroxysmal AF and 52 non-AF controls as test data. For each segment window length, discriminant models were made by fivefold cross-validation subsets of the training data and its classification performance was examined with the test data. RESULTS: In machine learning with the training data, the averages of cross-validation scores were 0.995 and 0.999 for 10 and 20-beat LP images, respectively, and > 0.999 for 50 to 500-beat images. The classification of test data showed good performance for all segment window lengths with an accuracy from 0.970 to 0.988. Positive likelihood ratio for detecting AF segments, however, showed a convex parabolic curve linear relationship to log segment window length and peaked at 85 beats, while negative likelihood ratio showed monotonous increase with increasing segment window length. CONCLUSIONS: This study suggests that the optimal segment window length that maximizes the positive likelihood ratio for detecting paroxysmal AF with 32 × 32-pixel LP image is 85 beats.
No takes yet. Share an insight, caveat, or question.
Kisohara et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: