Why the study?
Machine learning of R-R interval Lorenz plot images is promising for AF detection, but the optimal length of the R-R interval segment window is unknown.
Does a specific R-R interval segment length optimize the detection of paroxysmal atrial fibrillation using Lorenz plot images and machine learning?
Does a specific R-R interval segment length optimize the detection of paroxysmal atrial fibrillation using Lorenz plot images and machine learning?
An R-R interval segment length of 100 beats optimizes the detection of paroxysmal atrial fibrillation using Lorenz plot images and convolutional neural networks.
Answers are grounded in this paper and cite their sources.
85-beat segments optimize positive likelihood ratio for LP-based paroxysmal AF detection; leaves open prospective validation before clinical adoption.
Background Machine learning of R-R interval Lorenz plot (LP) images is a promising method for the detection of atrial fibrillation (AF) in long-term ECG monitoring, but the optimal length of R-R interval segment window for the LP images is unknown. We examined the performance of LP AF detection by differing the segment length using convolutional neural network (CNN). LP images with a 32 x 32-pixel resolution of non-overlapping R-R interval segments with lengths of 10, 20, 50, 100, 200, and 500 beats were created from 24-h ECG data in 52 patients with chronic AF and 58 non-AF controls as training data and in 53 patients with paroxysmal AF and 52 non-AF controls as test data. For each segment length, classification models were made by 5-fold cross-validation subsets of the training data and its classification performance was examined with the test data. Results In machine learning with the training data, the averages of cross-validation scores were 0.995 and 0.999 for 10 and 20-beat LP images, respectively, and >0.999 for 50 to 500-beat images. The classification of test data showed good performance for all segment lengths with an accuracy from 0.970 to 0.988. Positive likelihood ratio for detecting AF segments, however, showed a convex parabolic curve linear relationship to log segment length with a peak ratio of 111 at 100 beats, while negative likelihood ratio showed monotonous increase with increasing segment length. Conclusions This study suggests that the optimal R-R interval segment window length that maximizes the positive likelihood ratio for detecting paroxysmal AF with 32 x 32-pixel LP image is about 100 beats.
No takes yet. Share an insight, caveat, or question.
Kisohara et al. (2020) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: