An alternative implementation of an electrostatic MUT (Micromachined Ultrasonic Transducer), relying on multiple beams that displace along the chip’s surface instead of a single membrane displacing perpendicular to it, is presented in this work. With this approach, a design requiring a low bias voltage (24 V) and occupying a small area (3.3 ×3.3 mm², 2D/λ≈0.77) was shown to generate a sound pressure level of 82 dB (re. 20 µPa-rms) at 40 kHz and a distance of 8.9 cm. The high level of damping allows this transducer to operate in a wide frequency range (35–63 kHz). The operation of this device as an ultrasonic receiver was also proven. An implementation of this transducer as a rangefinder requires a strong reduction in the noise level, particularly coming from radio-frequency interference, in order to increase its detection range.
No takes yet. Share an insight, caveat, or question.
Monsalve et al. (2022) studied this question.