Capacitive (C) pressure sensors typically sense quadratic changes in C as a pressure difference (P) deflects a flexible conducting diaphragm near a rigid ground plane. Touch-mode capacitive pressure (C-P) sensors, where the conducting diaphragm touches a dielectric coated ground plane, often show a more linear response, but with less sensitivity, particularly at low-P. Initial contact of the diaphragm often occurs at a critical P. Until Pcritis reached, the sensitivity is typically too low for accurate measurements. In this work, two different types of electrodes with ldquoparabolicrdquo and ldquodonutrdquo cavity-shapes have been designed, fabricated, and tested to achieve high-sensitivity at low-pressures. A flexible conducting diaphragm touches the bottom electrode smoothly, and both cavity shapes permit initial contact at a zero-pressure differential. This type of C-P sensors can have touch-mode and peeling-mode operations. The sensitivities of these sensors in two operation modes were measured, and their resolutions were smaller than 0.1 Pa at a mean pressure of 105Pa. Both sensors in two modes have the resolution over total-pressure less than 106, which is difficult to achieve at atmospheric pressure.
No takes yet. Share an insight, caveat, or question.
Han et al. (2009) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: