Bone fractures affect approximately 178 million individuals annually worldwide, yet access to radiographic diagnosis remains limited in many clinical and resource-constrained settings. Using simulation-only data, this study investigates radio frequency (RF) sensing as a noninvasive, nonionizing, and portable complement to radiography for fracture screening and longitudinal healing assessment. A comprehensive 2-D finite-difference time-domain (2D-FDTD) electromagnetic framework was developed across three operating frequencies (1.0, 2.4, and 4.0 GHz), five anatomical sites (femur, tibia, ankle, wrist, and clavicle), three fracture-gap widths, and four fracture-healing stages. The term “physics-informed RF features” denotes signal descriptors selected because they correspond to electromagnetic propagation mechanisms in heterogeneous tissue: attenuation and scattering in the time domain, dielectric dispersion in the frequency domain, and fracture-induced disruption of spatial coherence across sensors. A total of 201 such features were extracted from seven-channel RF signals and evaluated using leakage-aware grouped cross-validation at the finite-difference time-domain (FDTD)-configuration level. Systematic evaluation on 15 600 noise-augmented samples showed that random forest achieved the highest binary fracture-discrimination performance (AUC-ROC = 0.832\,± \,0.046 ), whereas random undersampling boosting (RUSBoost) provided the most clinically favorable high-sensitivity operating point (99.0% sensitivity and 45.2% specificity). Leave-one-site-out (LOSO) evaluation demonstrated robust multisite transferability (AUC-ROC = 0.867\,± \,0.006 ), indicating that the learned RF signatures generalize across anatomically diverse skeletal locations without site-specific calibration. For healing assessment, direct five-class staging achieved 37.6%\,± \,2.8% accuracy. A clinically motivated three-class formulation (healthy, active healing, and advanced healing) achieved 61.2%\,± \,2.9% accuracy, corresponding to a 62.8% relative improvement over direct five-class staging, whilst targeted clinical questions achieved AUC-receiver operating characteristic (ROC) values of 0.77–0.83. Because no directly comparable external RF-based multisite grouped-validation healing-stage benchmark is available, state-of-the-art comparison is reported against the closest RF bone-assessment studies. Feature-importance and ablation analyses showed that time-domain statistics (63.5%) and cross-sensor correlations (25.0%) carry the dominant discriminative information, consistent with the physical hypothesis that fractures perturb RF amplitude and spatial coherence. These findings support RF sensing not as a replacement for radiographic imaging, but as a computationally validated candidate for rapid, radiation-free triage and interval monitoring, requiring phantom and clinical validation before deployment.
No takes yet. Share an insight, caveat, or question.
Aldelemy et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: