The intrinsic background was measured in LaBr 3 :Ce and CeBr 3 scintillating crystals grown at the Institute of Solid-State Physics of the Russian Academy of Sciences. The measurements were taken in the range of γ-ray energies from 20 keV to ∼5 MeV. Cylindrical samples with dimensions of Ø 1.5 × 1.8 cm for LaBr 3 :Ce and Ø 0.5 × 1.5 cm for CeBr 3 were used. Well-known peculiarities due to the 138 La radioactive iso-tope and actinide contaminants were reproduced in the recorded background spectrum of the LaBr 3 :Ce crystal. The detailed spectrum of the intrinsic background in the CeBr 3 crystal was measured for the first time. At energies of >200 keV, the background rate of CeBr 3 appeared to be much lower than that of LaBr 3 :Ce both in the continuum and in the peculiarities associated with the radioactivity of possible contaminants.
No takes yet. Share an insight, caveat, or question.
Iyudin et al. (2009) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: