Why the study?
Does catheter ablation (manual or RMN) provide acute and long-term success for IART or AVNRT in patients with d-TGA post-Mustard/Senning operation?
Does catheter ablation (manual or RMN) provide acute and long-term success for IART or AVNRT in patients with d-TGA post-Mustard/Senning operation?
Catheter ablation for IART or AVNRT in patients with d-TGA post-Mustard/Senning operation is highly effective, with remote magnetic navigation further improving procedural efficiency and success.
Answers are grounded in this paper and cite their sources.
Supports ablation for IART/AVNRT in d-TGA post-Mustard/Senning; leaves open RMN superiority in randomized trials.
AIMS: Data about the acute and long-term outcome of catheter ablation in patients with D-transposition of the great arteries (d-TGA) post-Mustard/Senning operation are scarce. METHODS AND RESULTS: This single-centre retrospective analysis includes 26 patients (mean age 28.7 ± 6.7 years, 8 females) after Mustard (n = 15) or Senning (n = 11) operation who underwent catheter ablation for intra-atrial re-entrant tachycardia (IART) or atrioventricular nodal re-entrant tachycardia (AVNRT) from January 2004 to May 2011. The electrophysiological studies were performed using a three-dimensional mapping system (CARTO). Remote magnetic navigation (RMN) was available since 2008. Follow-up on an outpatient basis was conducted 3, 6, and 12 months after ablation and yearly thereafter. In the 26 patients, 34 procedures were performed (one procedure n = 19, two n = 6, and three n = 1). Overall, 34 tachycardia forms (IART n = 30; AVNRT n = 4) were ablated manually (n = 25) or by RMN (n = 9). Acute success reached in 29/34 forms (85.3%). Mean fluoroscopy time (FT) was 28.2 ± 20.7 min and mean procedure duration (PD) was 290.9 ± 107.6 min. After a mean follow-up of 34.1 ± 24.5 months, 25/26 (96.2%) patients were free from IART or AVNRT. In the nine RMN ablations (mean follow-up 14.2 ± 5.8 months) acute and long-term success was 100%. Fluoroscopy time and PD were significantly reduced using RMN compared with manual ablation (11.9 ± 6.2 vs. 34.6 ± 20.6 min, 225.7 ± 24.1 vs. 312 ± 118.2 min, P = 0.02). CONCLUSION: Catheter ablation of IART or AVNRT in patients post-Mustard/Senning operation for d-TGA has a high acute success rate. The recurrence rate for IART is about 30%; however, after a second ablation, long-term results are excellent. Remote magnetic navigation seems to improve single-procedure acute and long-term success and significantly reduces FT and PD.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: