Why the study?
Does electrophysiologically guided amiodarone therapy predict recurrences and sudden death in patients with sustained ventricular arrhythmias?
Does electrophysiologically guided amiodarone therapy predict recurrences and sudden death in patients with sustained ventricular arrhythmias?
Electrophysiologically guided therapy with serial testing offers little benefit over empiric amiodarone for predicting sudden death in patients with sustained ventricular arrhythmias.
Electrophysiologic testing should not yet guide amiodarone management in ventricular arrhythmia patients; leaves open whether serial assessment improves outcomes over empiric therapy.
BACKGROUND: Programmed electrical stimulation early during amiodarone therapy has poor prognostic capabilities; and persistent inducibility has been associated with a favorable outcome in a majority of patients. These observations result from studies that differed significantly in methodology. METHODS AND RESULTS: The authors prospectively enrolled 121 patients in a standardized amiodarone dosing protocol in which amiodarone was the only antiarrhythmic agent. Electrophysiologic testing was done after 2 and 6 weeks to determine noninducibility, predictive value, and the significance of drug-induced prolongation of tachycardia cycle length. The mean age of the patients in the study was 63.2 +/- 11.5 years, and their ejection fraction was 32.8 +/- 11.9%. Coronary artery disease was present in 103 (85%). At 2 weeks 17 patients (14%) were no longer inducible, whereas 104 patients (86%) remained inducible. Patients in these groups were similar in age and ejection fraction. During follow-up evaluation, recurrences (35% vs 24%; P =.44) and sudden death (12% vs 13.5%) were similar in the two groups. Thirty-five of 95 patients (32%) with sustained monomorphic ventricular tachycardia had more than 100 ms prolongation of their cycle length, which was hemodynamically well tolerated (partial response), but 60 did not (nonresponse). Patients with a partial response were older (66.5 vs 61.1 years; P =.02) and had longer QRS durations (143.2 vs 129.4 ms; P =.03). They also had increased recurrences (37% vs 17%; P =.01) and more sudden deaths (23% vs 8%; P =.02). At 6 weeks 11 of 76 patients studied were noninducible. They had a lower recurrence rate than those who remained inducible (8% vs 27%; P =.02) but a similar number of sudden deaths (8% vs 16%; P =.27). Thirty-two patients partially responded, and 31 patients did not respond. During follow-up examination these two groups had a similar number of recurrences (25% vs 29%; P =.76) and sudden deaths (16% vs 16%). CONCLUSIONS: Noninducibility at 2 or 6 weeks of amiodarone therapy did not identify patients at low risk of sudden death. In inducible patients, tachycardia cycle length prolongation, even when well tolerated, was not a marker for favorable outcome. Electrophysiologically guided therapy, therefore, offers little benefit over empiric amiodarone.
No takes yet. Share an insight, caveat, or question.
Nasir et al. (1996) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: