A rearrangement of the geometry of cavity magnetron oscillators is proposed such that the magnetic field loops around the cathode, whereas waves and electrons travel along it. Application of various magnetron theories to the new geometry leads to the result that the device will oscillate under conditions similar to those for a conventional cavity magnetron. The required magnetic field can be generated by a heavy current passed axially through the cathode.
No takes yet. Share an insight, caveat, or question.
O. Buneman (1950) studied this question.