Answers are grounded in this paper and cite their sources.
In substituting a degree of imbalance between the phase impedances of HVdc converter transformers for the usual assumption of equal impedances, the generated ac harmonics are modified and triplen (non-characteristic) harmonics are produced. They are analysed and assessed; and are not expected to be serious provided due attention is paid to impedance balancing. Certain normal harmonics for 6-pulse operation are ideally eliminated by 12-pulse operation. An analysis is made of the extent of residual 6-pulse harmonics due to the imperfect balance of 12-pulse bridge operation. The paper provides a basis for specifying certain design tolerances.
No takes yet. Share an insight, caveat, or question.
Subbarao et al. (1976) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: