Why the study?
Does echocardiographic evaluation of AV-interval improve the combined endpoint of death or cardiac hospitalization in patients with chronic heart failure receiving CRT?
Does echocardiographic evaluation of AV-interval improve the combined endpoint of death or cardiac hospitalization in patients with chronic heart failure receiving CRT?
Echocardiographic optimization of the AV-interval in CRT patients is associated with a significant reduction in long-term mortality and cardiac hospitalization.
AV-interval optimization may benefit CRT recipients; hypothesis-generating and should not yet change practice.
BACKGROUND: Cardiac resynchronization therapy (CRT) is an established treatment option for symptomatic chronic heart failure (CHF) patients with pharmacological baseline therapy, but not all patients benefit from device therapy. One reason for this may be inadequate device settings. In real-world practice, echocardiographic evaluation of atrioventricular (AV) delay is not performed in a high proportion of patients, as the effect of electrical optimization of CRT is an issue open for investigation. MATERIALS AND METHODS: We performed a retrospective observational study analysing the effect of AV-interval evaluation with echocardiography on long-term [32 (23?43) months] clinical outcome in 205 CHF patients. A stepwise Cox regression model including a co-morbidity score, failed AV-interval evaluation, satisfactory device function after the first implantation attempt, failure to reach 100% of the recommended renin-angiotensin system inhibitor and beta-blocker dose at follow-up and CRT device implantation compared with CRT in combination with an implanted cardioverter defibrillator (ICD) was applied. RESULTS: In the total study cohort, 124 (60.5%) patients had reached the primary combined endpoint death or cardiac hospitalization and 59 (28.8%) had died. Cox regression analysis revealed that failed AV-interval evaluation [HR = 1.72 (1.19-2.49), P = 0.004] non-optimized CHF pharmacotherapy dosages [HR = 2.12 (1.32-3.42), P = 0.002], the presence of a CRT/ICD combination device [HR = 1.87 (1.28-2.71), P = 0.001] and satisfactory device function after the first implantation attempt [HR = 0.44 (0.25-0.77), P = 0.004] were associated with the primary endpoint. CONCLUSION: Echocardiographic evaluation of the AV-interval in patients with CRT was independently associated with improved clinical outcome, impacting on daily clinical practice of HF patient care.
No takes yet. Share an insight, caveat, or question.
Adlbrecht et al. (2010) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: