Population
Rabbit isolated Langendorff heart model (SCREENIT)
Comparison
55 marketed drugs or drugs intended for market vs 2 controls
Design
Preclinical, blinded manner
Authors
Loading...
Supports 30-fold safety margin in rabbit proarrhythmia screening; leaves open human TdP translation pending clinical validation.
The rabbit Langendorff heart model (SCREENIT) is a robust assay for predicting clinical Torsades de Pointes risk, with a 30-fold margin between effects and EFTPC(max) providing confidence for new chemical entities.
Lawrence et al. (2006) studied this question.