Why the study?
Does pressure-controlled intermittent coronary sinus occlusion (PICSO) increase coronary sinus and LAD wedge pressures in patients with stable angina undergoing LAD PCI?
Does pressure-controlled intermittent coronary sinus occlusion (PICSO) increase coronary sinus and LAD wedge pressures in patients with stable angina undergoing LAD PCI?
PICSO safely augments coronary sinus pressure and LAD coronary wedge pressure during PCI, supporting its potential to improve myocardial perfusion.
Answers are grounded in this paper and cite their sources.
May support PICSO pressure augmentation during LAD PCI; hypothesis-generating for perfusion benefit, needs randomized trials.
BACKGROUND: Myocardial reperfusion is frequently suboptimal after ST-segment elevation myocardial infarction (STEMI) treated by primary percutaneous coronary intervention (PCI). Using a balloon-tipped catheter positioned in the coronary sinus (CS), pressure-controlled intermittent coronary sinus occlusion (PICSO) results in an intermittent obstruction of coronary venous outflow of the left anterior descending artery (LAD), and may improve myocardial perfusion by augmenting redistribution of blood to the border zone of ischemic myocardium. We sought to document the intracoronary hemodynamic effects of PICSO during PCI. METHODS: We included 15 patients with stable angina scheduled for PCI of the LAD. Balloon occlusion of the LAD was performed twice, once with and once without PICSO and lasting maximally 3 minutes each, to document the effect of PICSO on CS pressure and LAD wedge pressure. RESULTS: Catheter delivery was successful in all patients. The study protocol could not be conducted in 5 patients due to initial calibration difficulties (n = 3), a pressure wire problem (n = 1), and a vagal response at the start of the procedure (n = 1). In the remaining 10 patients, CS occlusion caused a marked increase in mean CS pressure (4.1 ± 7.3 mmHg vs. 22.0 ± 12.6 mmHg; P < 0.001) and CS pulse pressure (4.3 ± 0.8 mmHg vs. 36.1 ± 6.3 mmHg; P < 0.001). Concomitantly, mean distal LAD wedge pressure and wedge pulse pressure increased (32.4 ± 12.2 mmHg vs. 35.5 ± 12.6 mmHg; P < 0.001 and 39.1 ± 27.2 mmHg vs. 45.9 ± 26.0 mmHg; P < 0.001, respectively). At 30 day follow-up, no device-related events occurred. CONCLUSIONS: PICSO safely augments CS pressure, thereby increasing LAD coronary wedge pressure. These findings support further evaluation of PICSO in the setting of STEMI.
No takes yet. Share an insight, caveat, or question.
Hoef et al. (2012) studied this question.