Answers are grounded in this paper and cite their sources.
Rabbits and monkeys were irradiated in the near field of a cavity-backed 2450 MHz resonant slot radiator, to determine the cataractogenic threshold. Rabbits developed cataracts at incident "apparent" power densities of 180 mW/cm2 (E2/120 pi, where E=rms/electric field strength). Monkeys sustained facial burns, but no lens damage, even at incident "apparent" power densities of 500 mW/cm2. These results were substantiated by computer thermal models.
No takes yet. Share an insight, caveat, or question.
Kramar et al. (1978) studied this question.