Why the study?
Acquiring high-quality CMR images in patients with frequent ventricular arrhythmias remains a challenge.
Does bolus intravenous procainamide suppress premature ventricular contractions and enable high-quality imaging in patients with frequent ventricular ectopics undergoing CMR scanning?
Does bolus intravenous procainamide suppress premature ventricular contractions and enable high-quality imaging in patients with frequent ventricular ectopics undergoing CMR scanning?
Bolus intravenous procainamide is a safe and effective strategy to suppress frequent PVCs and facilitate high-quality CMR imaging in patients with normal or mildly reduced systolic function.
Answers are grounded in this paper and cite their sources.
May facilitate high-quality CMR in frequent PVCs; leaves open need for randomized safety confirmation before routine use.
Acquiring high-quality cardiac magnetic resonance (CMR) images in patients with frequent ventricular arrhythmias remains a challenge. We examined the safety and efficacy of procainamide when administered on the scanner table prior to CMR scanning to suppress ventricular ectopy and acquire high-quality images. Fifty consecutive patients (age 53.0 [42.0-58.0]; 52% female, left ventricular ejection fraction 55 ± 9%) were scanned in a 1.5 T scanner using a standard cardiac protocol. Procainamide was administered at intermittent intravenous bolus doses of 50 mg every minute until suppression of the ectopics or a maximum dose of 10 mg/kg. The average dose of procainamide was 567 ± 197 mg. Procainamide successfully suppressed premature ventricular contractions (PVCs) in 82% of patients, resulting in high-quality images. The baseline blood pressure (BP) was mildly reduced (mean change systolic BP -12 ± 9 mmHg; diastolic BP -4 ± 9 mmHg), while the baseline heart rate (HR) remained relatively unchanged (mean HR change -1 ± 6 bpm). None of the patients developed proarrhythmic changes. Bolus intravenous administration of procainamide prior to CMR scanning is a safe and effective alternative approach for suppressing PVCs and acquiring high-quality images in patients with frequent PVCs and normal or only mildly reduced systolic function.
No takes yet. Share an insight, caveat, or question.
Nikolaidou et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: