Why the study?
Does synchronised diastolic injection reduce contrast volume compared to standard injection during aortography for PVR assessment in an in vitro model?
Does synchronised diastolic injection reduce contrast volume compared to standard injection during aortography for PVR assessment in an in vitro model?
A synchronised diastolic injection method significantly reduces contrast volume during aortography without compromising the accuracy of PVR assessment in an in vitro TAVI model.
Answers are grounded in this paper and cite their sources.
May reduce contrast use in TAVI aortography without losing PVR accuracy; leaves open clinical translation and patient outcomes.
AIMS: In the minimalist transcatheter aortic valve implantation (TAVI) era, the usage of transoesophageal echocardiography has become restricted. Conversely, aortography has gained clinical ground in quantifying prosthetic valve regurgitation (PVR) during the procedure. In a mock circulation system, we sought to compare the contrast volume required and the accuracy of aortographic videodensitometric PVR assessment using a synchronised diastolic and standard (non-synchronised) injection aortography. METHODS AND RESULTS: Synchronised diastolic injection triggered by the signal stemming from the mock circulation was compared with standard non-synchronised injection. A transcatheter heart valve was implanted and was deformed step by step by advancing a screw perpendicularly to the cage of the valve in order to create increasing PVR. Quantitative measurement of PVR was derived from time-density curves of both a reference area (aortic root) and a region of interest (left ventricle) developed by a videodensitometric software. The volume of contrast required for the synchronised diastolic injection was significantly less than in the non-synchronised injection (8.1 [7.9-8.5] ml vs. 19.4 [19.2-19.9] ml, p<0.001). The correlation between the two methods was substantial (Spearman's coefficient rho ranging from 0.991 to 0.968). Intraobserver intra-class correlation coefficient for both methods of injection was 0.999 (95% CI: 0.996-1.000) for the synchronised diastolic and 0.999 (95% CI: 0.996-1.000) for the non-synchronised injection group. The mean difference in the rating was 0.17% and limits of agreement were ±1.64% for both groups. CONCLUSIONS: A short synchronised diastolic injection enables contrast volume reduction during aortography without compromising the accuracy of the quantitative assessment of PVR using videodensitometry.
No takes yet. Share an insight, caveat, or question.
Miyazaki et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: