Why the study?
With the rise of minimalistic TAVR, aortography has re-emerged for AR assessment, prompting evaluation of an ECG-triggered low-volume diastolic injection in vivo.
Does a synchronized diastolic injection with low contrast volume improve the accuracy of quantitative aortic regurgitation assessment compared to conventional non-synchronized injection in a porcine model?
Does a synchronized diastolic injection with low contrast volume improve the accuracy of quantitative aortic regurgitation assessment compared to conventional non-synchronized injection in a porcine model?
Synchronized diastolic injection with low contrast volume provides denser images and more accurate quantitative assessment of aortic regurgitation than conventional injection in a porcine model, suggesting potential utility post-TAVR.
Answers are grounded in this paper and cite their sources.
May enable simplified AR assessment in minimalistic TAVR; extends mock validation but leaves clinical utility open pending prospective studies.
Objectives To evaluate the in vivo feasibility of aortography with one accurately timed diastolic low‐volume contrast injection for quantitative assessment of aortic regurgitation (AR) post transcatheter aortic valve replacement (TAVR). Background With the rise of a minimalistic approach for TAVR, aortography (re)emerges as a pragmatic tool for AR assessment. In a mock circulation system, we have validated the accuracy of a single diastolic injection triggered by electrocardiogram (ECG) with low‐contrast volume. Methods Two‐phase experiment: first, a series of aortograms were performed in a porcine model, with 8 mL of contrast using the synchronized (SYNC) and the conventional non‐synchronized (NS) injections. In a second phase, we developed a model of AR by inserting partially unsheathed Wallstents of 6–10 mm of diameter across the pig's aortic valve, performing SYNC injections with 8 mL of contrast and NS injections with 8 mL and 15 mL (rate: 20 mL/sec). Respective accuracies of SYNC vs. NS were assessed using Passing‐Bablock regression. An angiography core laboratory performed quantitative AR assessment with videodensitometry (VD‐AR). Results The SYNC injections produced higher opacification of the aortic root compared with NS injections ( P = 0.04 for density). In the second phase, a regression line for predicting VD‐AR based on the SYNC injection resulted in a lower intercept and a slope closer to the line of identity (y = 11.9 + 0.79x, P < 0.001, r 2 = 0.94) with the NS‐8 mL than with the NS‐15 mL injection (y = 26.5 + 0.55x, P < 0.001, r 2 = 0.81). Conclusion Synchronized diastolic injection with low contrast volume produced denser images in the aortic root and more accurate than the conventional injection; thus, may be an appealing alternative for assessment of AR post TAVR.
No takes yet. Share an insight, caveat, or question.
Modolo et al. (2018) studied this question.