Why the study?
Can non-invasive ultrasound Doppler and thermodilution cardiac output determinations quantify regurgitant flow in a patient with a paravalvular mitral fistula?
Can non-invasive ultrasound Doppler and thermodilution cardiac output determinations quantify regurgitant flow in a patient with a paravalvular mitral fistula?
Ultrasound Doppler combined with thermodilution cardiac output determinations can be of diagnostic value to quantify regurgitant flow when mitral valve implant malfunction is suspected.
Answers are grounded in this paper and cite their sources.
May aid quantification of paravalvular mitral regurgitant flow in select cases; leaves open validation before wider adoption.
Non-invasive ultrasound Doppler registrations and cardiac output determinations with a thermodilution catheter were performed in the presence of and after closure of a paravalvular mitral fistula in a 52-year-old patient with a 27 mm Björk-Shiley mitral valve. The data collected allowed the calculation of the regurgitant flow through the fistula. This study suggests that the method used can be of diagnostic value when mitral valve implant malfunction is suspected.
No takes yet. Share an insight, caveat, or question.
Høie et al. (1979) studied this question.