Why the study?
Epicardial clipping devices are used for LAA occlusion to prevent stroke, but the rate and determinants of incomplete occlusion have not been determined.
What is the incidence of and what are the morphologic determinants for incomplete left atrial appendage occlusion using an epicardial clipping device during robot-assisted mitral valve surgery?
What is the incidence of and what are the morphologic determinants for incomplete left atrial appendage occlusion using an epicardial clipping device during robot-assisted mitral valve surgery?
Approximately one-fourth of patients undergoing epicardial LAA clipping during robot-assisted mitral valve surgery had incomplete occlusion on follow-up CT—especially when the clip size exceeded the LAA ostium diameter by less than 10 mm—highlighting the need for preoperative CT sizing and routine intraoperative TEE verification.
Answers are grounded in this paper and cite their sources.
Incomplete LAA clip occlusion rates and morphologic predictors in robotic surgery are hypothesis-generating; prospective validation required before practice change.
Background Epicardial clipping devices are used for left atrial appendage (LAA) occlusion to prevent stroke. However, the rate and determinants of incomplete occlusion have not been determined. We clarified the rate of incomplete LAA occlusion and identified its morphologic determinants during robot-assisted minimally invasive surgery. Methods Between 2018 and 2024, 129 patients underwent LAA occlusion with a clip device during robot-assisted mitral surgery. Of them, 45 patients (median age, 67 years; 58% male) who underwent postoperative contrast-enhanced computed tomography were enrolled. The incidence of incomplete LAA occlusion (defined as contrast material detected in the LAA with stumps of >10 mm) was determined, with focus on the difference between the LAA ostium diameter and the size of the clip device. Results The median LAA ostium diameter at baseline was 29.3 mm (26.8-32.1 mm). The incomplete LAA occlusion was observed in 12 patients (26.7%), in 2 of whom large thrombi were demonstrated in the LAA. The rate of incomplete occlusion was significantly higher for cases in which the difference between the LAA ostium diameter and the size of the clip device was <10 mm (33.3% vs 0%; P < .026). Conclusions In selected patients who underwent LAA occlusion with a clip device during robot-assisted mitral surgery, approximately one-fourth showed incomplete LAA occlusion, presumably related to LAA morphology and clip device size. Although there might be some technical challenges of LAA occlusion through the transverse sinus approach, preoperative contrast-enhanced computed tomography assessment of the LAA could be employed to facilitate proper clip device selection and to reduce the risk of incomplete occlusion.
No takes yet. Share an insight, caveat, or question.
Hirayama et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: