Why the study?
Annular and LVOT calcification increase the risk of annular rupture after TAVR, and the outcomes of routinely using a balloon-expandable valve irrespective of calcium presence were unknown.
Does bespoke sizing of balloon-expandable valves by adjusting balloon deployment volume prevent annular rupture in patients undergoing TAVR?
Does bespoke sizing of balloon-expandable valves by adjusting balloon deployment volume prevent annular rupture in patients undergoing TAVR?
Bespoke sizing of balloon-expandable valves by adjusting balloon deployment volume safely avoids annular rupture during TAVR, even in patients with annular or LVOT calcification.
Bespoke BEV sizing may avoid annular rupture in calcified TAVR; leaves open need for prospective confirmation.
BACKGROUND: Annular and left ventricular outflow tract (LVOT) calcification increase the risk of annular rupture following transcatheter aortic valve replacement (TAVR). The outcomes of a strategy of routine use of a balloon-expandable valve (BEV) for all patients irrespective of annular or LVOT calcium is unknown. OBJECTIVES: We evaluated the impact of bespoke sizing on annular rupture in patients treated with a BEV. METHODS: All consecutive patients undergoing TAVR at a single centre (February 2020-February 2022) were treated only with a BEV. No other valve design was used. Annular/LVOT calcification was assessed using a standardized grading system. For each annular area, we determined the percentage valve oversizing with nominal deployment. The balloon deployment volume was then adjusted when required (over-/underfilled) to achieve over-sizing of approximately 5% in the presence of annular/LVOT calcium and 5%-10% in the absence of annular/LVOT calcium. Adjusted valve areas were assumed to change proportionately to the change in balloon deployment volume. RESULTS: Among 533 TAVR treated patients, annular/LVOT calcification was present in 166 (31.1%) and moderate or severe in 90 (16.9%). In patients with annular/LVOT calcification, the adjusted oversizing was 3.5 ± 3.6% and in patients without annular/LVOT calcification, the adjusted oversizing was 6.8 ± 4.7% (p < 0.001). There were no cases of annular rupture and no cases with more than mild paravalvular leak (PVL). Mild PVL was more frequent in patients with annular/LVOT calcium (10.8% vs 4.6%, p = 0.01). CONCLUSION: Bespoke BEV sizing by adjustment of balloon deployment volume avoided annular rupture in patients undergoing TAVR.
No takes yet. Share an insight, caveat, or question.
Chavarría et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: