The fluxmeter consists of a conducting system of small capacity which is alternately exposed to and screened from the electric field by the movement of a rapidly rotating metal shield, thus producing an alternating E M F. of period 0.83 millisecond The output, after amplification, is displayed on the screen of a cathode-ray oscillograph and the record carries an automatic indication of the sense of the field every 7.5 milliseconds At the maximum sensitivity employed the device gives a deflection of one centimetre in a field of 20 volts/metre, with a background noise-level of 0.15 cm. (3 volts/metre). The response-time of the instrument is one half-cycle (0 42 millisecond). The fluxmeter has been developed to give the rapid response and high sensitivity required for studies of the electric fields of thunderstorms in the intervals between the separate strokes of a lightning discharge.
No takes yet. Share an insight, caveat, or question.
Malan et al. (1950) studied this question.