Why the study?
Current methods for extracting the maximum velocity envelope in Doppler ultrasound cannot produce stable envelopes in high noise conditions, limiting clinical and research applications.
Does a new automatic envelope estimation method improve accuracy and beat segmentation in noisy Doppler ultrasound compared to existing methods?
Does a new automatic envelope estimation method improve accuracy and beat segmentation in noisy Doppler ultrasound compared to existing methods?
A novel automatic envelope estimation method for Doppler ultrasound improves accuracy and beat segmentation in high-noise conditions, potentially enhancing research and clinical monitoring applications.
Answers are grounded in this paper and cite their sources.
May stabilize Doppler velocity envelopes in noisy conditions; leaves open clinical validation before practice change.
Doppler ultrasound technology is widespread in clinical applications and is principally used for blood flow measurements in the heart, arteries, and veins. A commonly extracted parameter is the maximum velocity envelope. However, current methods of extracting it cannot produce stable envelopes in high noise conditions. This can limit clinical and research applications using the technology. In this article, a new method of automatic envelope estimation is presented. The method can handle challenging signals with high levels of noise and variable envelope shapes. Envelopes are extracted from a Doppler spectrogram image generated directly from the Doppler audio signal, making it less device-dependent than existing image-processing methods. The method's performance is assessed using simulated pulsatile flow, a flow phantom, and in vivo ascending aortic flow measurements and is compared with three state-of-the-art methods. The proposed method is the most accurate in noisy conditions, achieving, on average, for phantom data with signal-to-noise ratios (SNRs) below 10 dB, bias and standard deviation of 0.7% and 3.3% lower than the next-best performing method. In addition, a new method for beat segmentation is proposed. When combined, the two proposed methods exhibited the best performance using in vivo data, producing the least number of incorrectly segmented beats and 8.2% more correctly segmented beats than the next best performing method. The ability of the proposed methods to reliably extract timing indices for cardiac cycles across a range of signal quality is of particular significance for research and monitoring applications.
No takes yet. Share an insight, caveat, or question.
Latham et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: