To determine the feasibility of a study comparing the efficacy of an esophageal Doppler monitor-based fluid therapy algorithm with a heart rate- and mean arterial blood pressure-based algorithm in reducing hypotension and fluid load in anesthetized dogs.
Does an esophageal Doppler monitor-based fluid therapy algorithm reduce hypotension and fluid load compared to a heart rate and blood pressure-based algorithm in anesthetized dogs?
Does an esophageal Doppler monitor-based fluid therapy algorithm reduce hypotension and fluid load compared to a heart rate and blood pressure-based algorithm in anesthetized dogs?
A pilot study comparing EDM-based and HR/MAP-based fluid therapy algorithms in anesthetized dogs found no significant differences in hypotension or fluid volume, but was underpowered and deemed not feasible in its current form.
Supports feasibility of EDM-guided fluid therapy in anesthetized dogs; leaves open comparative efficacy versus HR/MAP algorithms.
The objective of this pilot study was to determine the feasibility of a study comparing the efficacy of an esophageal Doppler monitor (EDM)-based fluid therapy algorithm with a heart rate (HR)- and mean arterial blood pressure (MAP)-based algorithm in reducing hypotension and fluid load in anesthetized dogs. Client-owned dogs undergoing general anesthesia for surgical procedures were randomized to two groups. An EDM probe for monitoring blood flow in the descending aorta was placed in each dog before receiving a crystalloid bolus (5 mL/kg) over 5 min. Fluids were repeated in case of fluid responsiveness defined by increasing Velocity Time Integral (VTI) ≥ 10% in group EDM and by decreasing HR ≥ 5 beats/min and/or increasing MAP ≥ 3 mmHg in group standard. The feasibility outcomes included the proportion of dogs completing the study and the clinical applicability of the algorithms. The clinical outcomes were the total administered fluid volume and the duration of hypotension defined as MAP < 60 mmHg. Data was compared between groups with Mann-Whitney U -test. p < 0.05 were deemed significant. Of 25 dogs screened, 14 completed the study (56%). There were no differences in the proportion of recorded time spent in hypotension in group standard [2 (0–39)% (median (range))] and EDM [0 (0–63) %, p = 1], or the total volume of fluids [standard 8 (5–14) mL/kg/h, EDM 11 (4–20) mL/kg/h, p = 0.3]. This study declined the feasibility of a study comparing the impact of two newly developed fluid therapy algorithms on hypotension and fluid load in their current form. Clinical outcome analyses were underpowered and no differences in treatment efficacy between the groups could be determined. The conclusions drawn from this pilot study provide important information for future study designs.
No takes yet. Share an insight, caveat, or question.
Henze et al. (2022) studied this question.