The aims of this study were to calibrate the collection depth for RMS and, using the calibration, to evaluate the in‐depth phase transformation induced in a dental 3 Y ‐ TZP ceramic by hydrothermal aging, simulating LTD . Objectives 10x and 80x affording spatial resolutions of ~3 and ~1 μm, respectively, were used. Probe size was controlled by the confocal pinhole aperture. The collection depth of each probe (objective – pinhole combination) was calibrated on a wedge‐shaped pure tetragonal zirconia specimen. Pure tetragonal samples of a dental 3 Y ‐ TZP were aged in vitro in an autoclave, in Ringer solution, at 130°C, under 0.6 MPa, for 10, 15, 20, 25, and 90 h. Two specimens were used for each time interval and two unexposed specimens served as controls. Monoclinic volume fraction ( V fm ) was determined by X‐ray diffraction and by in‐depth probing with RCMS . Probes based on 10x objective penetrated up to 68 μm, whereas those based on the 80x were limited to 5 μm. Aging induced significant increase in V fm , ranging from 30% after 10 h to 80% after 90 h. After 90 h aging, the 80% V fm extended to at least 20 μm from the surface. A maximum V fm was identified at 2.5 μm subsurface depth in 10, 15, and 20 h aged specimens.