Four piezoelectric transducers with aluminum nitride (AlN), zinc oxide (ZnO), and bismuth titanate (BiTi) as the active elements and two magnetostrictive transducers were fabricated with Remendur and Galfenol as the active elements. The irradiation was for 18 months with an integrated neutron fluence of approximately 8.68 × 1020n/cm2for E > 1 MeV, temperatures in excess of 420 °C, and a gamma fluence of 7.23 × 1021gamma/cm2. The sensor performance is explained in the context of the pulse-echo signals. The feasibility of ultrasonic transducers in a nuclear reactor has been established. This opens the door to leave-in-place sensors for in-reactor conditions and materials.