Why the study?
Does a steroid-eluting passive fixation atrial lead improve stimulation thresholds compared to nonsteroid-eluting leads in patients requiring atrial pacing?
Does a steroid-eluting passive fixation atrial lead improve stimulation thresholds compared to nonsteroid-eluting leads in patients requiring atrial pacing?
Steroid-eluting passive fixation atrial leads maintain low stimulation thresholds over 18 months compared to nonsteroid-eluting leads, allowing for lower voltage programming without compromising sensing or dislodgment rates.
Answers are grounded in this paper and cite their sources.
May allow lower-output atrial pacing; leaves open randomized confirmation of clinical outcomes.
Although the original atrial pacing leads were passive fixation and J shaped for right atrial appendage placement, the subsequent development of the active fixation screw-in lead found favor because of a perceived low incidence of lead dislodgment and a wider selection of atrial pacing sites. A bipolar atrial lead study was undertaken to compare the long-term atrial implant data in 215 patients. Study leads comprised one passive fixation, steroid-eluting lead (Medtronic CapSure SP, 119 patients) and three nonsteroid-eluting leads; two active fixation (Medtronic BISPING model 4058, 30 patients; and Telectronics ACCUFIX model 330-801, 44 patients) and one passive fixation (Telectronics ENCOR model 330-854, 22 patients). Bipolar atrial voltage stimulation thresholds and electrograms were measured using the Telectronics META DDDR immediately postimplantation, and at 1-, 3-, 6-, 12-, and 18-month follow-up. There were 135 males and the mean age 68 years. The incidence of lead dislodgment was 4% for active fixation and 2% for passive fixation. All nonsteroid leads showed a typical rise in stimulation threshold with the highest being the ACCUFIX followed by the BISPING and ENCOR. The steroid-eluting CapSure SP, however, demonstrated a flat response with 98% of leads at 18 months having a value < or = 1.3 volts allowing voltage programming to 2.5 volts (2:1 safety ratio). Telemeted electrograms showed no differences for all leads at all visits. For low voltage atrial pacing with a low incidence of dislodgment and satisfactory atrial sensing, the steroid-eluting passive fixation lead is superior to all nonsteroid-eluting leads.
No takes yet. Share an insight, caveat, or question.
Mond et al. (1995) studied this question.