Key result
Left ventricular filling pressure assessed by E/A ratio and E/e' ratio independently predicted sinus rhythm maintenance at 12 months after electrical cardioversion.
Why the study?
To assess whether echocardiographic measurements of left atrial morphology and function could predict sinus rhythm maintenance after electrical cardioversion in patients with persistent AF and normal function or mild dysfunction of the LV.
Do echocardiographic measures of left ventricular filling pressure (E/A and E/e' ratios) predict maintenance of sinus rhythm at 12 months in patients with persistent atrial fibrillation after successful electrical cardioversion?
Cohort (n=117)
No
Do echocardiographic measures of left ventricular filling pressure (E/A and E/e' ratios) predict maintenance of sinus rhythm at 12 months in patients with persistent atrial fibrillation after successful electrical cardioversion?
Echocardiographic assessment of left ventricular filling pressure using E/A and E/e' ratios can independently predict the recurrence of atrial fibrillation 12 months after successful electrical cardioversion.
Answers are grounded in this paper and cite their sources.
Filling pressure indices may aid post-cardioversion rhythm prediction; hypothesis-generating and requires prospective validation before practice change.
BACKGROUND: The aim of this study was to assess whether echocardiographic measurements of left atrial (LA) morphology and function could predict sinus rhythm maintenance after electrical cardioversion among patients with atrial fibrillation (AF) and normal function or mild dysfunction of the left ventricle (LV). METHODS: One hundred seventeen patients with persistent AF who underwent successful electrical cardioversion were prospectively enrolled. Echocardiography was performed one day subsequent to successful cardioversion. Patients were followed up clinically and electrocardiographically at 1, 6, and 12 months. At 12 months, 61 (52%) patients had maintained sinus rhythm (SR). RESULTS: Compared to patients who maintained SR, those with AF recurrence had larger LAs, worse LA systolic function, and increased LV filling pressure. On multivariate stepwise logistic regression, E/A ratios (odds ratio [OR] 0.550, 95% confidence interval [CI] 0.341-0.886; p = 0.014) and E/e' ratios (OR 0.871, 95% CI 0.771-0.985; p = 0.027) were significant predictors of AF recurrence. On receiver operator characteristic curve analysis of AF recurrence at 12 months, the area under curve for both E/A and E/e' ratios were 0.726. With an E/A cutoff of 2.2, the sensitivity for predicting AF recur-rence at 12 months was 72%, and specificity was 73%. With an E/e' cutoff of 9.17, the sensitivity for predicting AF recurrence at 12 months was 72%, and specificity was 74%. CONCLUSIONS: Left ventricular filling pressure assessed with E/A and E/e' ratios predict AF recurrence after electrical cardioversions among patients with AF and normal function of LV.
No takes yet. Share an insight, caveat, or question.
Wałek et al. (2019) conducted a cohort in Persistent atrial fibrillation (n=117). Echocardiographic E/A and E/e' ratios was evaluated on Sinus rhythm maintenance at 12 months (OR 0.550, 95% CI 0.341-0.886, p=0.014). Left ventricular filling pressure assessed by E/A ratio and E/e' ratio independently predicted sinus rhythm maintenance at 12 months after electrical cardioversion.