Key result
Wearable optical heart rate sensors showed no significant difference in accuracy across skin tones, but absolute error during activity was on average 30% higher than during rest.
Why the study?
Wearables are increasingly used in healthcare, but no study had systematically explored their heart rate measurement accuracy across the full range of skin tones and under potential sources of error like motion.
Do wearable optical heart rate sensors maintain accuracy across different skin tones and activity levels?
Observational
Do wearable optical heart rate sensors maintain accuracy across different skin tones and activity levels?
Wearable optical heart rate sensors demonstrate consistent accuracy across different skin tones, but their error rate increases significantly during physical activity compared to rest.
Answers are grounded in this paper and cite their sources.
Supports equitable wearable HR monitoring across skin tones; leaves open activity error mitigation in validation studies.
UNSTRUCTURED As wearable technologies are being increasingly used for clinical research and healthcare, it is critical to understand their accuracy and determine how measurement errors may affect research conclusions and impact healthcare decision-making. Accuracy of wearable technologies has been a hotly debated topic in both the research and popular science literature. Currently, wearable technology companies are responsible for assessing and reporting the accuracy of their products, but little information about the evaluation methods is made publicly available. Heart rate measurements from wearables are derived from photoplethysmography (PPG), an optical method for measuring changes in blood volume under the skin. Potential inaccuracies in PPG stem from three major areas, including: 1) diverse skin types, 2) motion artifacts, and 3) signal crossover. To date, no study has systematically explored the accuracy of wearables across the full range of skin tones. Here, we explored heart rate and PPG data from consumer- and research-grade wearables under multiple circumstances to test whether and to what extent these inaccuracies exist. We saw no statistically significant difference in accuracy across skin tones, but we saw significant differences between devices, and between activity types, notably, that absolute error during activity was, on average, 30% higher than during rest. Our conclusions indicate that different wearables are all reasonably accurate at resting and prolonged elevated heartrate, but that differences exist between devices in responding to changes in activity. This has implications for researchers, clinicians and consumers in drawing study conclusions, combining study results, and making health-related decisions using these devices.
No takes yet. Share an insight, caveat, or question.
Bent et al. (2020) reported an observational. Wearable optical heart rate sensors vs. Resting state / different skin tones was evaluated on Accuracy of heart rate measurements across skin tones and activity types. Wearable optical heart rate sensors showed no significant difference in accuracy across skin tones, but absolute error during activity was on average 30% higher than during rest.