Key result
Failure to comply with the SCIP INF1 measure was not significantly associated with surgical site infection rates (0 SSIs among 43 noncompliant patients out of 703 total).
Why the study?
Does compliance with the SCIP surgical site infection module reduce surgical site infection rates in surgical patients?
Observational (n=703)
Does compliance with the SCIP surgical site infection module reduce surgical site infection rates in surgical patients?
Compliance with the SCIP prophylactic antibiotic timing measure did not correlate with reduced surgical site infection rates, suggesting it should not be used to determine reimbursement rates.
SCIP INF1 noncompliance was not associated with SSIs in this cohort; leaves open its value as a quality metric or for reimbursement.
The Surgical Care Improvement Project (SCIP) is a project that focuses on improving surgical care by reducing surgical morbidity and mortality by 25 per cent by 2010. Starting in 2011, SCIP compliance affects Medicare and Medicaid reimbursement rates. Although SCIP reinforces better practices in surgical care, does compliance with SCIP measures actually result in a decrease in surgical morbidity and mortality? This study examined compliance with the SCIP surgical site infection (SSI) module (prophylactic antibiotic received within 1 hour before surgical incision) during 2009 to 2010 (n = 703) to determine whether patients compliant with SCIP data had a correlation with SSI rates as reported by National Surgery Quality Improvement Program (NSQIP) data for the same time period. We found no statistically significant association in patients that have failed SCIP INF1 in the years 2009 to 2010 (n = 43) and the rates of SSI (n = 0) for the same time period. These data suggest that SCIP compliance should not be used to determine Medicare and Medicaid reimbursement rates because there is no correlation between failure of SCIP INF1 and SSI. Instead, further effort should be placed on developing tools designed to acknowledge outcome measures that result in decreased morbidity/mortality and change practices accordingly such as NSQIP.
No takes yet. Share an insight, caveat, or question.
Garcia et al. (2012) conducted an observational in Surgical site infection (n=703). Failure of SCIP INF1 compliance vs. SCIP INF1 compliance was evaluated on Surgical site infection (SSI) rates. Failure to comply with the SCIP INF1 measure was not significantly associated with surgical site infection rates (0 SSIs among 43 noncompliant patients out of 703 total).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: