Key result
Cardiovascular magnetic resonance feature tracking demonstrated excellent inter-observer reproducibility for global longitudinal strain at baseline in a porcine model.
Why the study?
Although CMR-FT is standardized in humans, comparative analysis data from animal models is scarce.
Is cardiovascular magnetic resonance feature tracking (CMR-FT) reproducible for assessing global strain in pig models under various inotropic states?
Is cardiovascular magnetic resonance feature tracking (CMR-FT) reproducible for assessing global strain in pig models under various inotropic states?
CMR-FT is a highly reproducible technique for assessing myocardial strain in pig models, enabling future preclinical trials with small sample sizes.
Answers are grounded in this paper and cite their sources.
Supports preclinical CMR-FT validation in porcine models; leaves open human reproducibility and clinical translation.
Cardiovascular magnetic resonance feature tracking (CMR-FT) is a novel technique for non-invasive assessment of myocardial motion and deformation. Although CMR-FT is standardized in humans, literature on comparative analysis from animal models is scarce. In this study, we measured the reproducibility of global strain under various inotropic states and the sample size needed to test its relative changes in pigs. Ten anesthetized healthy Landrace pigs were investigated. After baseline (BL), two further steps were performed: (I) dobutamine-induced hyper-contractility (Dob) and (II) verapamil-induced hypocontractility (Ver). Global longitudinal (GLS), circumferential (GCS) and radial strain (GRS) were assessed. This study shows a good to excellent inter- and intra-observer reproducibility of CMR-FT in pigs under various inotropic states. The highest inter-observer reproducibility was observed for GLS at both BL (ICC 0.88) and Ver (ICC 0.79). According to the sample size calculation for GLS, a small number of animals could be used for future trials.
No takes yet. Share an insight, caveat, or question.
Faragli et al. (2020) studied Healthy (n=10). Cardiovascular magnetic resonance feature tracking (CMR-FT) was evaluated on Inter-observer reproducibility of global longitudinal strain (GLS) at baseline (ICC 0.88, 95% CI 0.57-0.97). Cardiovascular magnetic resonance feature tracking demonstrated excellent inter-observer reproducibility for global longitudinal strain at baseline in a porcine model.
Synapse has enriched 10 related papers. Consider them for comparative context: