Key result
A SAMe-TT2R2 score >5 predicted poor anticoagulation control with a sensitivity of 0.49, specificity of 0.68, and a limited C-statistic of 0.548.
Why the study?
Warfarin remains widely used for stroke prevention in non-valvular atrial fibrillation in Asian countries, but the SAMe-TT2R2 score requires validation for predicting poor anticoagulation control in the Malaysian population.
Does the SAMe-TT2R2 score predict poor anticoagulation control in Malaysian patients with non-valvular atrial fibrillation on warfarin?
Cohort (n=957)
Yes
Does the SAMe-TT2R2 score predict poor anticoagulation control in Malaysian patients with non-valvular atrial fibrillation on warfarin?
The SAMe-TT2R2 score >5 predicts poor anticoagulation control in a Malaysian cohort, but its limited predictive capability (C-statistic 0.548) suggests cautious interpretation and consideration of additional factors.
Introduction: In Asian countries, warfarin is still widely used for stroke prevention in non-valvular atrial fibrillation compared to non-vitamin K antagonist oral anticoagulants (NOACs) due to its affordability. A tool such as the SAMe-TT 2 R 2 is needed to determine the probability of achieving and maintaining good anticoagulation control with warfarin therapy. However, it requires validation in the Malaysian cohort. Therefore, the objective of our study is to validate the SAMe-TT 2 R 2 score in predicting poor anticoagulation control in Malaysia. A time in therapeutic range (TTR) < 65% was used to determine poor anticoagulation control. Method: This retrospective cohort study was conducted from July 2022 to July 2023. Patients were enrolled in 2020 from 49 facilities located across Malaysia resulting in a total of 957 included patients. TTR was calculated using Roseendaal’s method. Results: The mean (SD) TTR and SAMe-TT 2 R 2 score in the overall cohort is 65.2% (±24) and 5.5 (±0.9) respectively. Almost half of the population (43.7%) has the SAMe-TT 2 R 2 score of 5. Having diabetes, ischemic heart disease, and increasing HAS-BLED and SAMe-TT 2 R 2 score affects anticoagulation control on univariate analysis. However, after adjusting for demographics and clinical variables on multivariate analysis, only the SAMe-TT 2 R 2 score as a continuous variable persists in predicting poor anticoagulation control. A SAMe-TT 2 R 2 score cut-off point of >5 best predicts poor anticoagulation control with a sensitivity of 0.49 and a specificity value of 0.68. Conclusion: The SAMe-TT 2 R 2 score, especially when exceeding 5, was associated with a higher likelihood of poor anticoagulation control, emphasizing its relevance in clinical assessment. However, its limited predictive capability, reflected by a C-statistic of 0.548, suggests the need for cautious interpretation and consideration of additional factors in anticoagulation management decisions. Continuous monitoring and personalized strategies are crucial for optimizing outcomes in this population.
No takes yet. Share an insight, caveat, or question.
Mohamed et al. (2024) conducted a cohort in non-valvular atrial fibrillation (n=957). SAMe-TT2R2 score > 5 vs. SAMe-TT2R2 score ≤ 5 was evaluated on Poor anticoagulation control (Time in therapeutic range < 65%). A SAMe-TT2R2 score >5 predicted poor anticoagulation control with a sensitivity of 0.49, specificity of 0.68, and a limited C-statistic of 0.548.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: