Key result
Among veterans with HFrEF receiving an ICD, 1-year mortality was significantly higher in the oldest age quartile compared to the youngest quartile (32.3% vs 7.0%).
Why the study?
Guidelines advise ICD implantation in patients with a life expectancy >1 year, prompting an examination of trends in all-cause mortality following ICD placement in the Veterans Affairs Health System.
What is the 1-year mortality rate following ICD placement in US veterans with HFrEF, and how does it vary by age?
Cohort (n=17,901)
Yes
What is the 1-year mortality rate following ICD placement in US veterans with HFrEF, and how does it vary by age?
Absolute Event Rate: 32.3% vs 7%
There is a high 1-year mortality rate (over 32%) in elderly veterans with HFrEF receiving ICDs, highlighting the need for better mortality prediction models to guide appropriate patient selection.
Age should inform ICD shared decision-making in HFrEF veterans; leaves open net survival benefit by age.
AIMS: Implantable cardioverter-defibrillator (ICD) therapy reduces mortality in patients with heart failure and current guidelines advise implantation of ICDs in patients with a life expectancy of >1 year. We examined trends in all-cause mortality in patients who underwent primary or secondary prevention ICD placement in the Veterans Affairs (VA) Health System. METHODS AND RESULTS: US veterans receiving a new ICD placement for primary or secondary prevention of sudden cardiac death between January 2007 and January 2015, who had heart failure with reduced ejection fraction (HFrEF) were included in the analysis. We assessed all-cause mortality 1 year post-ICD implantation. ICD implantation and HFrEF diagnosis were established with associated ICD-9 codes. The VA death registry was utilized to identify mortality rates following ICD placement. Results were subsequently age-stratified. There were 17 901 veterans with HFrEF with ICD placement nationwide. There was no statistically significant difference in 1-year mortality from 2007 (13.1%) to 2014 (13.4%, P > 0.05). There was a significant increase in 1-year mortality in patients in the oldest age quartile (81.6 years, 32.3% mortality) compared to the youngest quartile (55.5 years, 7% mortality). The finding of diverging clinical outcomes extended to the 30-day but also 8-year mark. CONCLUSIONS: Our data suggest there is a high 1-year mortality in aging HFrEF patients undergoing primary and secondary prevention ICD placement. This highlights the importance of developing better predictive models for mortality in our ICD eligible patient population.
No takes yet. Share an insight, caveat, or question.
Fudim et al. (2020) conducted a cohort in Heart failure with reduced ejection fraction (HFrEF) (n=17,901). Implantable cardioverter-defibrillator (ICD) placement in oldest age quartile vs. ICD placement in youngest age quartile was evaluated on 1-year all-cause mortality. Among veterans with HFrEF receiving an ICD, 1-year mortality was significantly higher in the oldest age quartile compared to the youngest quartile (32.3% vs 7.0%).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: