The inactivation of simian rotavirus SA-11 and human rotavirus type 2 (Wa) by ozone was compared at 4 degrees C by using single-particle virus stocks. Although the human strain was clearly more sensitive, both virus types were rapidly inactivated by ozone concentrations of 0.25 mg/liter or greater at all pH levels tested. Comparison of the virucidal activity of ozone with that of chlorine in identical experiments indicated little significant difference in rotavirus-inactivating efficiencies when the disinfectants were used at concentrations of 0.25 mg/liter or greater.
No takes yet. Share an insight, caveat, or question.
Vaughn et al. (1987) studied this question.