Answers are grounded in this paper and cite their sources.
EXPERIMENTAL and theoretical studies have been made of the impulse received by a target surface when irradiated by a high-power pulsed CO2 laser at reduced ambient pressures. Correlation of experimental and theoretical results for aluminum targets indicates a maximum impulse-energy coupling coefficient ap~2 dyn s/J and an effective thermal coupling coefficient a,—0.1. Both theory and experiment show an increase in ap with increasing ambient pressure. Structural deformation was experimentally demonstrated for an 1100 aluminum target. Contents Most of the previous work on impulse transfer from highpower laser pulses to surfaces, both experimental and theoretical, has been carried out for ambient air at or near 1 atm pressure, the measured impulse being dominated by the air environment.1 The air above the target surface can become ionized, forming an absorptive plasma. At laser intensities above about 107 W/cm2, this air plasma moves supersonically up the laser beam and away from the target, shielding the target surface from further direct radiation. This phenomenon is the well-known laser-supported detonation (LSD).2'3 At low ambient pressures (densities), on the other hand, impulse data are more limited in quantity, and theoretical predictions and correlations are comparatively less well established. As the ambient pressure is lowered, the air plasma absorption length for laser energy increases, becoming comparable to or exceeding the width of the laser beam; the LSD wave in air becomes harder to maintain and eventually disappears.3 In such cases, vaporization of the target material and the subsequent behavior of the vapor become the dominant factor in determining the impulse transfer. In the present work, both experimental measurements and theoretical calculations have been made of the impulse received by a target surface when irradiated by a high-power pulsed CO2 laser at reduced ambient pressures. The impulse experiments were carried out inside a 120-cmdiamx 160-cm-long vacuum tank. The pressure was varied from 10 to 0.01 Torr. The laser beam was admitted through a scintered NaCl window whose outside face was tilted to avoid reflecting energy back into the laser cavity. The 7.5-cm-diam beam was concentrated on the target by means of a copper mirror having a focal length of 114 cm located in the vacuum tank. By adjusting the distance between the mirror and the target, the laser spot diameter was varied from 0.38 to 2.3 cm.
No takes yet. Share an insight, caveat, or question.
Shui et al. (1978) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: