The mixing of spanwise-varying coolant in hypersonic laminar flow is numerically and experimentally examined. Simulations were performed using US3D at Mach 7 with nitrogen injection at blowing ratios ranging from 0.0406% to 0.295% through a spanwise stepped blowing profile. Experiments were conducted at Mach 6.25 flows with unit Reynolds numbers of [Formula: see text] and [Formula: see text]. Argon, nitrogen, and helium were injected with blowing ratios from 0.0468% to 0.313% through injectors with varied uniformity. Pressure-sensitive paint was applied on a flat-plate model to spatially resolve the coolant film downstream of the injector. Results demonstrate that the coolant can be tailored with a spanwise-varying injection up to a limited streamwise distance. However, regardless of the initial injection profile, the film eventually converges to a Gaussian profile farther downstream. At a chosen blowing ratio, helium’s larger volume can saturate the film concentration to unity, diminishing the imposed spanwise profile entirely. In contrast, the spanwise profile is retained for the cases of nitrogen or argon. A comparison of these cases with a case of helium with a lower blowing ratio shows a similar retention of the spanwise profile downstream. However, the spanwise profile is not as prominent in the case of helium, likely because of its approximately three times higher diffusion coefficient compared to that of nitrogen or argon.