Key result
Right-left cusp fusion in BAV is linked to higher peak gradients, but right-noncoronary to greater aortopathy.
Why the study?
Patients with bicuspid aortic valves tend to develop dilation of the ascending aorta, but the impact of leaflet fusion pattern remains to be clarified.
Does bicuspid aortic valve leaflet fusion morphology impact aortopathy severity and aortic root diameter in young adults undergoing aortic valve replacement?
Observational (n=90)
Does bicuspid aortic valve leaflet fusion morphology impact aortopathy severity and aortic root diameter in young adults undergoing aortic valve replacement?
Answers are grounded in this paper and cite their sources.
R/N fusion may prompt closer preoperative aortic surveillance in BAV; leaves open long-term progression differences by pattern.
Methods: We performed a retrospective review of 90 patients with aortic valve disease (mean age 51.5±8.2 years) who underwent aortic valve replacement with or without concomitant aortic surgery for BAV (n=60) and TAV (n=30) between 2012 and 2017. Fusion of right-left coronary cusps was identified in 45 patients (R/L group), while the remaining 15 patients had rightnoncoronary cusp fusion (R/N group). BAVs were identified via echocardiography or MRI. Aortic diameter was measured at 4 levels, and Z values were computed. Results: There was no significant difference between the BAV and TAV groups with respect to age, weight, presence of concomitant Bentall procedure, grade of AI, and size of implanted prosthesis (Table). Higher preoperative peak gradient on aortic valve was significantly associated with R/L fusion (p=0.02). Preoperative Z values of ascending aorta and sinotubular junction were significantly higher in patients with R/N fusion when compared to R/L and TAV subgroups (Figure). During followup (mean, 2.0±1.5 years), three patients underwent a redo procedure (one of each group).
No takes yet. Share an insight, caveat, or question.
Bibevski et al. (2019) conducted an observational in Aortic valve disease (n=90). Bicuspid aortic valve leaflet fusion morphology (right-left vs right-noncoronary cusp fusion) vs. Tricuspid aortic valve (TAV) was evaluated on Preoperative peak aortic valve gradient, aortic Z values, and redo procedures (p=0.02). Right-left cusp fusion was associated with higher preoperative peak aortic valve gradients, while right-noncoronary fusion had higher ascending aorta Z values.
Synapse has enriched 10 related papers. Consider them for comparative context: