Why the study?
Does transient hypercapnia induce shear-mediated dilation of the internal carotid artery independent of concurrent hypercapnia in healthy participants?
Does transient hypercapnia induce shear-mediated dilation of the internal carotid artery independent of concurrent hypercapnia in healthy participants?
Hypercapnia induces shear-mediated dilation of the internal carotid artery in humans, suggesting a potential method for assessing cerebrovascular health.
May inform cerebrovascular reactivity testing but should not yet alter practice; leaves open distinct CO2 versus shear stress contributions to carotid dilation.
Evidence for shear stress as a regulator of carotid artery dilation in response to increased arterial CO 2 was recently demonstrated in humans during sustained elevations in CO 2 (hypercapnia); however, the relative contributions of CO 2 and shear stress to this response remains unclear. We examined the hypothesis that, after a 30-s transient increase in arterial CO 2 tension and consequent increase in internal carotid artery shear stress, internal carotid artery diameter would increase, indicating shear-mediated dilation, in the absence of concurrent hypercapnia. In 27 healthy participants, partial pressures of end-tidal O 2 and CO 2 , ventilation (pneumotachography), blood pressure (finger photoplethysmography), heart rate (electrocardiogram), internal carotid artery flow, diameter, and shear stress (high-resolution duplex ultrasound), and middle cerebral artery blood velocity (transcranial Doppler) were measured during 4-min steady-state and transient 30-s hypercapnic tests (both +9 mmHg CO 2 ). Internal carotid artery dilation was lower in the transient compared with steady-state hypercapnia (3.3 ± 1.9 vs. 5.3 ± 2.9%, respectively, P < 0.03). Increases in internal carotid artery shear stress preceded increases in diameter in both transient (time: 16.8 ± 13.2 vs. 59.4 ± 60.3 s, P < 0.01) and steady-state (time: 18.2 ± 14.2 vs. 110.3 ± 79.6 s, P < 0.01) tests. Internal carotid artery dilation was positively correlated with shear rate area under the curve in the transient ( r 2 = 0.44, P < 0.01) but not steady-state ( r 2 = 0.02, P = 0.53) trial. Collectively, these results suggest that hypercapnia induces shear-mediated dilation of the internal carotid artery in humans. This study further promotes the application and development of hypercapnia as a clinical strategy for the assessment of cerebrovascular vasodilatory function and health in humans. NEW & NOTEWORTHY Shear stress dilates the internal carotid artery in humans. This vasodilatory response occurs independent of other physiological factors, as demonstrated by our transient CO 2 test, and is strongly correlated to shear area under the curve. Assessing carotid shear-mediated dilation may provide a future avenue for assessing cerebrovascular health and the risk of cerebrovascular events.
No takes yet. Share an insight, caveat, or question.
Hoiland et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: