Answers are grounded in this paper and cite their sources.
Three-phase voltage-source converters are used as utility interfaces. In such a case, the converter line currents are required to track sinusoidal references synchronized with the utility grid without a steady-state error. In this paper a current control method based on a sinusoidal internal model is employed. The method uses a sine transfer function with a specified resonant frequency, which is called an S regulator. The combination of a conventional proportional-integral (PI) regulator and an S regulator is called a PIS regulator. The PIS regulator ensures that the steady-state error in response to any step changes in a reference signal at the resonant frequency and 0 Hz reduces to zero. An experiment was carried out using a 1-kVA prototype of three utility-interface converters, a voltage-source rectifier, an active power filter, and static synchronous compensator. Almost perfect current-tracking performance could be observed.
No takes yet. Share an insight, caveat, or question.
Fukuda et al. (2005) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: